资源类型

期刊论文 212

会议视频 8

年份

2023 8

2022 21

2021 26

2020 19

2019 11

2018 7

2017 4

2016 19

2015 7

2014 8

2013 9

2012 8

2011 15

2010 17

2009 8

2008 6

2007 7

2006 2

2005 1

2004 5

展开 ︾

关键词

天然气 9

地位 2

天然产物 2

天然气水合物 2

性能化 2

气流组织 2

环境 2

能源 2

21世纪 1

CFD 1

CO2 加氢 1

COVID-19 1

LDV/APV 1

LNG冷能 1

SARS-CoV-2 1

SEEA2012–CF 1

WTO 1

三星一线 1

专用技术装备 1

展开 ︾

检索范围:

排序: 展示方式:

Impacts of opening baffle of city road tunnels on natural ventilation performance

Weixiao YANG, Jincheng XING, Jianxing LI, Jihong LING, Haixian HAO, Zhiqiang YAN

《结构与土木工程前沿(英文)》 2013年 第7卷 第1期   页码 55-61 doi: 10.1007/s11709-013-0194-x

摘要: Based on the opening baffle mode for natural ventilation of city road tunnels, this paper studies the impacts of opening baffle on natural ventilation performance by verifying numerical simulation through model tests. By analyzing the impacts of installation angle, dimension, location, and quantity of opening baffle on ventilation performance, the paper reached the conclusions as follows: 1) When installation angle is larger than 45° and tunnel ventilation is well operated, the baffle exhaust could increase by at least 30% compared to when there is no baffle. 2) The baffle reaches its optimal performance when the length of the baffle is equal to the width of the city road tunnels. 3) Baffle exhaust could increase by 30% when it is installed in the downstream of openings. 4) The performance of a single baffle is better than that of multiple baffles.

关键词: city road tunnel     numerical simulation     baffle     top opening     natural ventilation    

终南山公路隧道非机械式通风效果研究

郑晅,郭佳奇

《中国工程科学》 2010年 第12卷 第3期   页码 39-44

摘要:

秦岭终南山特长公路隧道规模庞大,通风系统复杂,为了合理确定通风配置,节约通风费用,评估自然风和交通活塞风等非机械式通风方式的通风效果就显得非常重要。课题组现场监测了终南山特长公路隧道内的自然风速、交通量及自然风压和交通风压共同作用下的风速,收集了大量数据。通过对监测数据的处理、分析得出,较大自然风速出现在10∶00—14∶00这个时间段,最大自然风速达到2.576 m/s;隧道东、西线交通量出现高峰期的时间段基本恒定;隧道东线内自然风压和交通风压共同作用下的风速较大的时间段基本上与交通量高峰期时间段相吻合,而西线这两个时间段吻合性较差,洞内风速变化相对平缓。考虑洞口外风向频率、风向、洞口实测温度等参数的自然风速计算方法计算值与实测自然风速较接近。隧道内自然风压和交通风压联合作用下的风速计算值虽小于现场实测值,但较接近实测值。

关键词: 隧道通风     现场监测     非机械式通风     自然风     交通活塞风    

Designs and practices of energy saving in Lhasa Railway Station

Kai CUI, Yungang PAN, Lixin SHAN,

《能源前沿(英文)》 2010年 第4卷 第1期   页码 106-116 doi: 10.1007/s11708-010-0011-3

摘要: The design, construction, operation and on-site measurement of Lhasa Railway Station was summarized. The problems and corresponding solutions during the implementation of building energy saving design and utilization of solar energy were proposed.

关键词: building energy saving     natural ventilation     solar energy     radiant floor heating    

A survey of decorative materials on the energy consumption of mid-rise residential buildings in Mashad, Iran

Masoud Taheri SHAHRAEIN, Lihua ZHAO, Qinglin MENG

《结构与土木工程前沿(英文)》 2010年 第4卷 第4期   页码 490-497 doi: 10.1007/s11709-010-0068-4

摘要: Polyvinylchloride (PVC) panel is one of the most favorite decorative materials that has been popularly applied as finishing of ceiling in residential buildings. It is about five years that the people incline to redecorate the ceiling of old buildings with PVC panel in big cities of Iran, such as Mashad. In this study, the influence of ceiling PVC panel on the cooling and heating loads of studied apartment were determined by software DeST-h. In addition, the summer natural ventilation of the mentioned apartment is investigated by determining the wind speed into the apartment through the computational fluid dynamics (CFD) software. The evaluation of environment indoor wind velocity showed that most of the apartment space is a comfortable zone. The results of studied building analyses demonstrated that using PVC panel on the ceiling can decline the energy consumption of the penthouse (fifth level) of the investigated building, which is about 3.7% and 7% for studied methods of without and with air layer, respectively. In addition, although the existence of air layer can decline the cooling and heating loads, the increase in air layer thickness did not show significant decrease on building energy consumption. However, the PVC panel is expensive and is not suitable to be used for ceiling thermal insulation, but adding a thin layer of air between ceiling and PVC panel can be a good step toward sustainable building, when the people are inclined to utilize it as a decorative ceiling.

关键词: residential apartments     natural ventilation     energy consumption     decorative materials     Mashad    

Full-scale site evaluation of ventilation expressway embankments underlain by warm permafrost along the

《结构与土木工程前沿(英文)》   页码 1047-1059 doi: 10.1007/s11709-023-0034-6

摘要: Ventilation embankments, including those with forced ventilation, natural ventilation, and combination of these, were adopted for the construction of the Gonghe−Yushu Expressway in warm permafrost areas. To evaluate the actual thermal performance of ventilation embankment in the Qinghai−Tibet Plateau, four types of ventilation embankments were selected as objects, and their long-term thermal characteristics were analyzed based on monitoring data. It was found that: 1) under the strong scale effect of a wide embankment, the crushed-rock embankment (CRE) was warming up and the permafrost table was declining year by year. Meanwhile, the combined ventilated slab and CRE and ventilated ducts embankment can effectively decrease the ground temperature and raise permafrost table in the year with a colder winter; 2) transverse temperature difference caused by the shady–sunny slope effect existed in all the four embankments. However, it was weakened by the combined ventilated slab and CRE and the ventilated ducts embankment due to their stronger cooling effect; and 3) the pre-existing embankment had a remarkable thermal disturbance to the adjacent newly-built embankment, so a reasonable embankment spacing should be considered in practical engineering. These findings would provide a reference for construction of expressway embankments in permafrost regions.

关键词: warm permafrost     expressway     ventilation embankments     temperature field    

独头巷道空气年龄及通风有效性评价研究

王海桥,田峰,黄俊歆,陈涛

《中国工程科学》 2007年 第9卷 第11期   页码 43-47

摘要:

根据独头巷道作业空间的特点,给出了独头巷道局部空气年龄、平均空气年龄的定义及其计算模型,用示踪气体测定平均空气年龄的方法和原理,并用CFD (computational fluid dynamics)对独头巷道附壁受限射流通风流场及平均空气年龄进行了数值计算,得出了独头巷道空间通风流场和平均空气年龄分布,建立了计算换气效率和排污效率的数学模型。研究表明影响通风有效性的主要因素是空气年龄和污染物浓度,而影响空气年龄主要是通风气流组织和通风量。为评价独头巷道通风有效性提供了一种新的理论依据。

关键词: 独头巷道     平均空气年龄     通风有效性     换气效率     排污效率    

Prevention of surgical site infection under different ventilation systems in operating room environment

Zhijian Liu, Haiyang Liu, Hang Yin, Rui Rong, Guoqing Cao, Qihong Deng

《环境科学与工程前沿(英文)》 2021年 第15卷 第3期 doi: 10.1007/s11783-020-1327-9

摘要: Abstract • The effectiveness of four different ventilation systems was compared in depth. • Airflow and bacteria-carrying particles concentration were quantitatively analyzed. • Vertical laminar airflow with high airflow rate could not achieve desired effect. • Temperature-controlled airflow ventilation could guarantee air cleanliness. Biological particles in the operating room (OR) air environment can cause surgical site infections (SSIs). Various ventilation systems have been employed in ORs to ensure an ultraclean environment. However, the effect of different ventilation systems on the control of bacteria-carrying particles (BCPs) released from the surgical staff during surgery is unclear. In this study, the performance of four different ventilation systems (vertical laminar airflow ventilation (VLAF), horizontal laminar airflow ventilation (HLAF), differential vertical airflow ventilation (DVAF), and temperature-controlled airflow ventilation (TAF)) used in an OR was evaluated and compared based on the spatial BCP concentration. The airflow field in the OR was solved by the Renormalization Group (RNG) k-e turbulence model, and the BCP phase was calculated by Lagrangian particle tracking (LPT) and the discrete random walk (DRW) model. It was found that the TAF system was the most effective ventilation system among the four ventilation systems for ensuring air cleanliness in the operating area. This study also indicated that air cleanliness in the operating area depended not only on the airflow rate of the ventilation system but also on the airflow distribution, which was greatly affected by obstacles such as surgical lamps and surgical staff.

关键词: Operating room (OR)     Bacteria-carrying particles (BCPs)     Surgical site infections (SSIs)     Ventilation    

整合矿井复杂通风系统的优化改造

张付涛

《中国工程科学》 2011年 第13卷 第11期   页码 68-71

摘要:

唐山沟煤矿作为资源整合矿井,存在通风系统复杂和安全隐患多等一系列问题,通过通风阻力测定、风机性能测试和通风系统合理可靠性评价,查找原有矿井通风系统存在的问题,分析其主要原因,提出了通风系统优化改造方案。经实施后,降低了通风系统阻力,提高了矿井通风系统稳定性和抗灾能力。

关键词: 整合矿井     复杂通风系统     优化改造    

Successful management of seven cases of critical COVID-19 with early noninvasive–invasive sequential ventilation

Mian Peng, Xueyan Liu, Jinxiu Li, Di Ren, Yongfeng Liu, Xi Meng, Yansi Lyu, Ronglin Chen, Baojun Yu, Weixiong Zhong

《医学前沿(英文)》 2020年 第14卷 第5期   页码 674-680 doi: 10.1007/s11684-020-0796-3

摘要: We report the clinical and laboratory findings and successful management of seven patients with critical coronavirus disease 2019 (COVID-19) requiring mechanical ventilation (MV). The patients were diagnosed based on epidemiological history, clinical manifestations, and nucleic acid testing. Upon diagnosis with COVID-19 of critical severity, the patients were admitted to the intensive care unit, where they received early noninvasive–invasive sequential ventilation, early prone positioning, and bundle pharmacotherapy regimen, which consists of antiviral, anti-inflammation, immune-enhancing, and complication-prophylaxis medicines. The patients presented fever ( = 7, 100%), dry cough ( = 3, 42.9%), weakness ( = 2, 28.6%), chest tightness ( = 1, 14.3%), and/or muscle pain ( = 1, 14.3%). All patients had normal or lower than normal white blood cell count/lymphocyte count, and chest computed tomography scans showed bilateral patchy shadows or ground glass opacity in the lungs. Nucleic acid testing confirmed COVID-19 in all seven patients. The median MV duration and intensive care unit stay were 9.9 days (interquartile range, 6.5–14.6 days; range, 5–17 days) and 12.9 days (interquartile range, 9.7–17.6 days; range, 7–19 days), respectively. All seven patients were extubated, weaned off MV, transferred to the common ward, and discharged as of the writing of this report. Thus, we concluded that good outcomes for patients with critical COVID-19 can be achieved with early noninvasive–invasive sequential ventilation and bundle pharmacotherapy.

关键词: COVID-19     noninvasive–invasive sequential ventilation     bundle pharmacotherapy    

Biodegradation of triclosan and triclocarban in sewage sludge during composting under three ventilation

Bao Yu, Guodi Zheng, Xuedong Wang, Min Wang, Tongbin Chen

《环境科学与工程前沿(英文)》 2019年 第13卷 第3期 doi: 10.1007/s11783-019-1125-4

摘要:

TCS and TCC can be biodegraded during sewage sludge composting.

Ventilation significantly accelerated the biodegradation of TCS and TCC in sludge.

Composting can reduce the environmental risk of TCS and TCC in sewage sludge.

关键词: Sewage sludge     Compost     Triclosan     Triclocarban     Ventilation     Risk assessment    

渤海海峡隧道施工通风方案探讨

吴元金,邹翀

《中国工程科学》 2013年 第15卷 第12期   页码 90-94

摘要:

由于海上施工竖井布设难度大,致使渤海海峡隧道独头单口掘进长度加大,几个工作面独头单口掘进长度都在25 km左右。本文采用渤海海峡隧道现有的设想方案,通过通风方式的选择、通风计算和通风设备选型对本工程的施工通风进行研究,提出利用巷道式通风解决独头单口掘进25 km隧道施工通风的方案,为渤海海峡隧道的可行性研究提供施工通风方面的技术支持。

关键词: 渤海海峡隧道     施工通风     巷道式通风     方案设计    

A concept of capillary active, dynamic insulation integrated with heating, cooling and ventilation, air

Mark BOMBERG

《结构与土木工程前沿(英文)》 2010年 第4卷 第4期   页码 431-437 doi: 10.1007/s11709-010-0071-9

摘要: When a historic fa?ade needs to be preserved or when the seismic considerations favor use of a concrete wall system and fire considerations limit exterior thermal insulation, one needs to use interior thermal insulation systems. Interior thermal insulation systems are less effective than the exterior systems and will not reduce the effect of thermal bridges. Yet they may be successfully used and, in many instances, are recommended as a complement to the exterior insulation. This paper presents one of these cases. It is focused on the most successful applications of capillary active, dynamic interior thermal insulation. This happens when such insulation is integrated with heating, cooling and ventilation, air conditioning (HVAC) system. Starting with a pioneering work of the Technical University in Dresden in development of capillary active interior insulations, we propose a next generation, namely, a bio-fiber thermal insulation. When completing the review, this paper proposes a concept of a joint research project to be undertaken by partners from the US (where improvement of indoor climate in exposed coastal areas is needed), China (indoor climate in non-air conditioned concrete buildings is an issue), and Germany (where the bio-fiber technology has been developed).

关键词: capillary active insulation     integrated heating     cooling and ventilation     air conditioning (HVAC) and building enclosure     dynamic insulation     switchable thermal resistance     variable U-value walls    

适应性贴附通风——负压呼吸性传染病隔离病房有效性的比较研究 Article

张莹, 韩欧, 李安桂, 侯立安, Thomas Olofsson, 张林华, 雷文君

《工程(英文)》 2022年 第8卷 第1期   页码 130-137 doi: 10.1016/j.eng.2020.10.020

摘要:

新型冠状病毒的传播给隔离病房的室内环境控制提出了挑战。科学的气流组织设计和运行管理是保证医护人员环境安全的关键。本文提出了适应性贴附通风在隔离病房的应用,并从污染物扩散、去除效率、热舒适性和运行费用等方面对这种送风方式进行了评估。适应性贴附通风将新鲜空气直接、较好地供应至医护人员工作区。与顶送风或侧壁上送风相比,在相同的污染物释放率和房间换气次数(ACH; 10 h-1)条件下,适应性贴附通风的污染物平均浓度降低了15% ~ 47%。理想的混合通风的污染物去除效率不能超过1.0。对于适应性贴附通风,污染物去除效率是换气次数的指数函数。与顶送风模式或侧壁上送风模式相比,适应性贴附通风可实现相似的热舒适水平[预测平均评价(PMV)为-0.1~0.4;吹风感为2.5%~6.7%],且以较低的换气次数和能耗获得相似去除污染物的性能。

关键词: 通风效率     换气率     COVID-19     贴附通风     气流组织     隔离病房    

A logic-based controller for the mitigation of ventilation air methane in a catalytic flow reversal reactor

Zhikai LI, Zhangfeng QIN, Yagang ZHANG, Zhiwei WU, Hui WANG, Shuna LI, Mei DONG, Weibin FAN, Jianguo WANG

《化学科学与工程前沿(英文)》 2013年 第7卷 第3期   页码 347-356 doi: 10.1007/s11705-013-1347-0

摘要: The control system of a catalytic flow reversal reactor (CFRR) for the mitigation of ventilation air methane was investigated. A one-dimensional heterogeneous model with a logic-based controller was applied to simulate the CFRR. The simulation results indicated that the controller developed in this work performs well under normal conditions. Air dilution and auxiliary methane injection are effective to avoid the catalyst overheating and reaction extinction caused by prolonged rich and lean feed conditions, respectively. In contrast, the reactor is prone to lose control by adjusting the switching time solely. Air dilution exhibits the effects of two contradictory aspects on the operation of CFRR, i.e., cooling the bed and accumulating heat, though the former is in general more prominent. Lowering the reference temperature for flow reversal can decrease the bed temperature and benefit stable operation under rich methane feed condition.

关键词: ventilation air methane     reverse flow reactor     lean methane combustion     logic-based controller     mathematical modeling    

地铁客室通风板模型数值模拟及实验研究 Article

陶羽, 杨明智, 钱博森, 伍钒, 王田天

《工程(英文)》 2019年 第5卷 第2期   页码 329-336 doi: 10.1016/j.eng.2018.12.007

摘要:

列车客室内流场研究是轨道列车设计及优化中的关键一环。内流场特性对车内温度分布及乘客舒适性有着显著影响。针对内流场的实验研究可获得较准确的结果,但需要大量时间和经济成本。数值模拟相对于实验可在更短时间内获得内流场特性。本文采用两种简化模型(多孔介质模型和多孔阶跃面模型)来提升轨道列车客室内流场数值模拟的计算效率。将两种简化模型及原始模型的数值模拟结果与实验数据进行比较。结果表明,多孔介质模型的结果与原始模型结果以及实验数据吻合得较好,其流场特性参数(温度和速度)的数值误差较小,最大数值误差为4.71%。在原始模型和多孔介质模型的数值模拟结果中,同一参数之间的数值误差在1% 以内。采用多孔介质模型替代原始模型进行地铁列车客室内流场数值模拟,所占用的计算资源相应减少了25%,且其结果保持了很好的准确性。

关键词: 数值模拟     实验     通风板模型     地铁    

标题 作者 时间 类型 操作

Impacts of opening baffle of city road tunnels on natural ventilation performance

Weixiao YANG, Jincheng XING, Jianxing LI, Jihong LING, Haixian HAO, Zhiqiang YAN

期刊论文

终南山公路隧道非机械式通风效果研究

郑晅,郭佳奇

期刊论文

Designs and practices of energy saving in Lhasa Railway Station

Kai CUI, Yungang PAN, Lixin SHAN,

期刊论文

A survey of decorative materials on the energy consumption of mid-rise residential buildings in Mashad, Iran

Masoud Taheri SHAHRAEIN, Lihua ZHAO, Qinglin MENG

期刊论文

Full-scale site evaluation of ventilation expressway embankments underlain by warm permafrost along the

期刊论文

独头巷道空气年龄及通风有效性评价研究

王海桥,田峰,黄俊歆,陈涛

期刊论文

Prevention of surgical site infection under different ventilation systems in operating room environment

Zhijian Liu, Haiyang Liu, Hang Yin, Rui Rong, Guoqing Cao, Qihong Deng

期刊论文

整合矿井复杂通风系统的优化改造

张付涛

期刊论文

Successful management of seven cases of critical COVID-19 with early noninvasive–invasive sequential ventilation

Mian Peng, Xueyan Liu, Jinxiu Li, Di Ren, Yongfeng Liu, Xi Meng, Yansi Lyu, Ronglin Chen, Baojun Yu, Weixiong Zhong

期刊论文

Biodegradation of triclosan and triclocarban in sewage sludge during composting under three ventilation

Bao Yu, Guodi Zheng, Xuedong Wang, Min Wang, Tongbin Chen

期刊论文

渤海海峡隧道施工通风方案探讨

吴元金,邹翀

期刊论文

A concept of capillary active, dynamic insulation integrated with heating, cooling and ventilation, air

Mark BOMBERG

期刊论文

适应性贴附通风——负压呼吸性传染病隔离病房有效性的比较研究

张莹, 韩欧, 李安桂, 侯立安, Thomas Olofsson, 张林华, 雷文君

期刊论文

A logic-based controller for the mitigation of ventilation air methane in a catalytic flow reversal reactor

Zhikai LI, Zhangfeng QIN, Yagang ZHANG, Zhiwei WU, Hui WANG, Shuna LI, Mei DONG, Weibin FAN, Jianguo WANG

期刊论文

地铁客室通风板模型数值模拟及实验研究

陶羽, 杨明智, 钱博森, 伍钒, 王田天

期刊论文